Optical Multimedia photo Taken from the documents on Electrohydrodynamics at the T Townsend Brown family website."It became clear at this stage that the idealized electrode structure included an anode of bi-arcuate or tri-arcuate shape; in other words, helmet shaped. The cathode, much smaller in size (preferably annular or ring-shaped) is positioned concentrically within the helmet anode and aligned with its rim. Heating the cathode to incandescence greatly increases the plasma density in the region between the two electrodes. Bleeding alkali vapor into the region near the cathode further increases the plasma density. The anode and the cathode are mechanically tied together by a ceramic spacing member.
When electrically energized to the limit, just under electrical breakdown, high energy plasma is generated in the region immediately adjacent to the incandescent cathode where the electric field density is greatest. By highly effective electrostriction due to the unique geometry of the field, the plasma is accelerated toward all portions of the concave anodic surface, creating hydrostatic pressure against said surface. It is within this region, extending outward to the periphery of the anode, that the plasma receives its principle acceleration. It is then driven beyond the rim and flows with high velocity in a circuit back to the cathode. The flow pattern takes the form of a toroidal vortex. Contact by convection with the ambient plasma forces the ambient in a direction opposite to that of the hydrostatic pressure acting upon the surface of the anode. This is required for conservation of momentum.
It has thus become clear that the arcuate anode experiences a net thrust due to what may be the equivalent to aerodynamic pressure; hence, it becomes a type of airfoil capable of lift.
Tests in a vacuum chamber up to 0.001 microns have revealed a remarkable constancy of this lift with diminishing pressure. Two inter-related possibilities may provide an explanation:
1) The ion density of the plasma, as represented in terms of dielectric constant does not decrease with pressure, and
2) The plasma velocity increases with the mean free path.
Static pressures at various points on the concave side of the arcuate anode are readily measured by manometers. A pressure profile for any given anode shape can thus be obtained. It is noted that the integrated pressure derived from any profile agrees remarkably well with the observed static thrust. With an arcuate anode or so called "canopy" of 80 cm. diameter, the thrust at 250 KV and 2 mA. is of the order of 110,000 dynes.
This thrust, acting as lift, causes a tethered model weighing about 100 grams to hover in the air, lifting not only its own weight but supporting a "payload" of 10 grams." (Also see note 17).
|